Important Drum Pump Safety Information

Safety Usage Guide for Acids and Alkalis

The stronger the concentration of the chemicals being transferred, the shorter the life of the pump. Before each use, the pump, hose and seal around the shaft should be examined for any trace of leakage. A visual inspection should also be made for any signs of swelling or cracking. Should any leak or defect be found, it is time to replace the pump.

Extreme care should be taken when handling any hazardous liquid. Protective clothing including eye goggles and face shield should be worn to protect the operator from any splash or spill during the transfer.

If you are using more than one chemical, it is strongly suggested that a separate pump be assigned to each chemical. This will insure against contamination and chemical reaction.

Should it be necessary to use the same pump for different chemicals, extreme care should be taken to assure that the pump is cleaned between uses. Should the pump contain any concentrated acid when it is flushed with water, an exothermic chemical reaction could result in the destruction of the pump.

Do NOT pump to a level higher than the pump itself. If necessary, raise the container. The receptacle should always be equal to or lower than the pump.

Always use the adapters to hold pump to container. This allows you to pump with one hand, and to hold the hose and direct flow with the other.

READ ALL SAFETY INSTRUCTIONS BEFORE USING PUMPS.

Special pumps are manufactured to transfer specific chemicals and are marked at the factory for these specific usages. They should not be used to transfer any other chemical.

Safety Usage Guide for Flammable Liquids

Please be careful. The major dangers in storing or handling flammable liquids are those of fire and explosion.

Storage containers should be grounded if made of conductive material and should not be near sources of sparks, open flames or hot surfaces. The container should be kept in an area where spillage (liquid or vapors) will not flow to an ignition source. DO NOT ALLOW SMOKING IN THE AREA. Be sure to provide adequate ventilation to prevent concentration of fumes. Remember, fumes of flammable liquids are highly explosive. Fire extinguishers suitable for chemical fires should be readily available. Water is generally not suitable as an extinguisher of a chemical fire. Ensure means of safe disposal of any spillage before transferring. Liquid should only be transferred to an approved safety container. If such a container is conductive then it should be connected to the storage container with a grounding strap to prevent static electric spark.

Before each use, a visual inspection of the pump should be made for any signs of cracking or leaking. Should any defect be found it is time to replace the pump.

Guidelines for handling flammable liquids can be obtained from the National Fire Protection Agency, Batterymarch Park, Quincy, Massachusetts 02269

KEEP AWAY FROM CHILDREN
Always remove pump from container when not in use.


CHEMICAL GUIDE

E.I. duPont de Nemours & Co has a chemical resistance guide available on their web site here.

DO NOT use the Beckson pump with the following chemicals:

 

Acetone

Amyl Acetate

Aniline

Aromatic Hydrocarbons

Benzaldehyde

Benzoyl Chloride

Bromine, Anhydrous Liquid

Butyl Acetate

Butyraldehyde

Carbon Tetrachloride

Chromic Acid

Ethyl Acetate

Lacquers

Ethyl Chloride

Lacquer Solvents

Methyl Ethyl Ketone

Naphthalene

Toluene

Trichloroethylene

Solvents

Xylene

When in doubt regarding the chemical compatibility of the pump or liquid, call or write ETS at:

Tel: (610) 583 -7657 Fax: (610) 583 -5479

20 E. Winona Ave, Norwood, PA 19074


Disclaimer of Warranties

ALL PRODUCTS SOLD BY EQUIPMENT TRADE SERVICE CO. INC. ARE DISTRIBUTED ON AN "AS IS" BASIS WITHOUT EXPRESS OR IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Should any product prove defective, the purchaser's sole remedy shall be limited to the replacement of the product proved to be defective. Under no circumstances shall Equipment Trade Service Co. Inc. be liable for any liability, loss or damage, direct, incidental or consequential, arising out of the use of, or inability to use, any product. Before using any product, user shall determine the suitability of the product for his intended use, and user assumes all risk and liability whatsoever in connection therewith. The foregoing may not be changed except by agreement signed by officers of Equipment Trade Service Co. Inc.


VITON®, HYPALON® and Delrin® are Registered Trademarks of E.I. duPont de Nemours & Co.

E.I. duPont de Nemours & Co has a chemical resistance guide available on their web site here.


Acid Transfer Pumps | Alkali Transfer Pumps | FDA Listed Pumps
Petroleum Hand Pumps | Sanitary Maintenance Pumps | Dairy Chemical Transfer Pumps
Pool Pumps and Accessories | Water Pumps | Adapters
Bucket Dolly | Multi-use Drum Wrench | Stainless Pick / Probe
 

Equipment Trade Service Co. Inc. 20 E. Winona Ave. Norwood, PA 19074 Ph: 610-583-7657 Fax: 610-583-5479
Copyright © 2003 Equipment Trade Service Co., Inc. All Rights Reserved. | Disclaimer/TOU | Privacy Policy